Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1455893.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/29/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/12/2020
Gravity: 10
Report ID: 0523900
Contest Date: 06/22/2020
Final Order: 11/25/2020
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 03/23/2021 | $0.00 | 06/12/2020 | Serious | |
| Penalty | F: Formal Settlement | 11/25/2020 | $0.00 | 06/12/2020 | Serious | |
| Penalty | Z: Issued | 05/29/2020 | $0.00 | 06/12/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Building 23, depalletizing robot cell; On or about January 9, 2020, electrical and pneumatic sources of energy were not isolated while maintenance operations were performed on the pusher table section of an automated depalletizing robot (Fanuc, model M410-iB, robot # 2). An employee injury occurred, which resulted in hospitalization.