Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1450104.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/14/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/09/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/09/2020 | $0.00 | Serious | ||
| Penalty | Z: Issued | 05/14/2020 | $0.00 | Serious | 
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 3, 2019, employees were exposed to hazardous coke oven gas during the isolation and blanking of gas lines. The employer failed to implement energy control application steps as LOTO devices were not applied to lock open the water seal valves [per 1910.147(d)(4) requirements.] As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards. LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished.
 Translate
Translate