Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1448885.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/05/2020
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/18/2020
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 03/10/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/05/2020 | $0.00 | 02/18/2020 | Serious | 
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29CFR 1910.147(c)(4)(ii)[A], 29CFR 1910.147(c)(4)(ii)[B], 29CFR 1910.147(c)(4)(ii)[C], and 29CFR 1910.147(c)(4)(ii)[D]: a) Kentwood M609HD Moulder Machine: On December 4, 2019 and at times prior, the employer exposed employees to potential hazardous energy sources such as but not limited to, electrical and kinetic, in that the written procedures did not include specific steps for verifying that electrical and kinetic energy was controlled. b) Lift Table: On December 4, 2019 and at times prior, the employer exposed employees to potential hazardous energy sources such as but not limited to, electrical, in that the written procedures did not include specific steps for verifying that electrical energy was controlled.
 Translate
Translate