Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1421566.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/30/2020
Nr Instances: 4
Nr Exposed: 2
Abatement Date: 02/05/2020
Gravity: 10
Report ID: 0316100
Contest Date:
Final Order: 03/03/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/30/2020 | $0.00 | 02/05/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) Airframe Bearings Lab, Constant Load Test Stand 1: On or about July 31, 2019, employee was exposed to the ingoing nip points of the chains and sprockets while operating the equipment without the guards in place. (b) Airframe Bearings Lab, Constant Load Test Stands 1, 2 and 3: On or about August 6, 2019, the expanded metal guards did not adequately protect employees in that the two guards on top had ½ inch openings located approximately ¼ inch from the chains and sprockets underneath. (c) Airframe Bearings Lab, Constant Load Test Stands 1, 2 and 3: On or about August 6, the expanded metal guards did not adequately protect employees in that the guards on the sides of the equipment had ½ inch openings located approximately 2 inches from the chains and sprockets underneath. (d) Airframe Bearings Lab, Constant Load Test Stands 1, 2 and 3: On or about August 6, the lower portion of each test stand had an opening in front that measured approximately 9-1/2 inches by 28-1/4 inches, exposing employees to the moving chains and sprockets underneath. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate