Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1414516.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/15/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/12/2019
Gravity: 10
Report ID: 0316400
Contest Date: 12/02/2019
Final Order: 04/01/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/01/2020 | $0.00 | 12/12/2019 | Serious | |
Penalty | C: Contested | 12/17/2019 | $0.00 | 12/12/2019 | Serious | |
Penalty | Z: Issued | 11/15/2019 | $0.00 | 12/12/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Line 10: On July 9, 2019 and times prior, employees would perform servicing and maintenance activities on the 8" Cumberland pelletizer without first turning off or shutting down the equipment, to include addressing the gravitational energy as well as the 480V electrical energy. (b) 17" Pelletizer: On or about October 23, 2019 and times prior, employees would perform servicing and maintenance activities on the 17" Cumberland pelletizer without first fully turning off or shutting down the equipment, to include addressing the approximately 75psi pneumatic energy and 480V electrical energy.