Violation Detail
Standard Cited: 19260651 J02 Specific Excavation Requirements.
Inspection Nr: 1402669.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,630.00
Current Penalty: $0.00
Issuance Date: 10/02/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0213100
Contest Date: 11/12/2019
Final Order: 05/26/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/26/2020 | $0.00 | Serious | ||
Penalty | C: Contested | 11/18/2019 | $6,630.00 | Serious | ||
Penalty | Z: Issued | 10/02/2019 | $6,630.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) Southeast corner of excavation, while building forms and rebar assemblies: On or prior to 5/9/19, employees were exposed struck-by hazards from a rebar bundle placed within 2' of the edge of the excavation.