Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1394677.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 07/24/2019 2
Initial Penalty: $5,304.00
Current Penalty: $0.00
Issuance Date: 06/06/2019
Nr Instances: 1
Nr Exposed: 9
Related Event Code (REC):
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 06/27/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/27/2019 | $0.00 | 07/24/2019 | Serious | |
Penalty | Z: Issued | 06/06/2019 | $5,304.00 | 07/24/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Facility, 2319 Beans Cove Road, Clearville, PA: On or about April 19, 2019 the employer had not provided any training to employees who service or maintain equipment to ensure they understood the purpose and function of energy control or had the knowledge and skills for safe application usage and removal of control devices. Employees service equipment such as, but not limited to: trimmers, edgers, debarkers, hog/chipper, or pelletizer and no training has been provided to ensure employees are protected when performing such tasks.