Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1381768.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 04/25/2019
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 05/30/2019
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 05/20/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/20/2019 | $0.00 | 05/30/2019 | Serious | |
Penalty | Z: Issued | 04/25/2019 | $9,282.00 | 05/30/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about February 28, 2019, the employer failed to conduct a periodic inspection, at least annually, of their Lock Out Tag Out Program to ensure that it was up to date and effective. The last documented review of this program was in December of 2014. Lock Out and Tag Out are being performed on various machines, including but not limited to the QH 1030 press brake and the Cincinnati shearer press.