Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1372872.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/21/2019
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 03/28/2019
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 03/19/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/19/2019 | $0.00 | 03/28/2019 | Serious | |
| Penalty | Z: Issued | 02/21/2019 | $0.00 | 03/28/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft ends did not present a smooth edge and projected more than one-half the diameter of the shaft: (a) Leprino Foods 2400 East Beaver Avenue, Fort Morgan, CO 80701: On or before 01-16-19, the employer did not ensure that a shaft end on the SEM conveyor was guarded. The shaft projected 3/4 inch from the external frame of the conveyor and measured approximately 3/4 inch in diameter. The edge of the shaft was not smooth in that a keyway projected from the end of the shaft. This condition exposed employees to the hazard of getting caught in the rotating part.
Translate