Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1362582.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 04/11/2019 2
Initial Penalty: $0.00
Current Penalty: $13,260.00
Issuance Date: 04/03/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 04/30/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2019 | $13,260.00 | 04/11/2019 | Serious | |
Penalty | Z: Issued | 04/03/2019 | $0.00 | 04/11/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) North building - On or about November 28, 2018 the employer had not performed adequate training for employees who are affected when energy control procedures are applied to the Farrell Compound Mixer exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing tasks including but not limited to start-up, maintenance, servicing, and jam clearing.