Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1356836.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/19/2018
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 01/08/2019
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 12/11/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/11/2018 | $0.00 | 01/08/2019 | Serious | |
| Penalty | Z: Issued | 11/19/2018 | $0.00 | 01/08/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a. During the unjamming of a Switchback box forming machine an employee did not apply energy controls by; turning off and/or shutting down the press [per the 1910.147(d)(2) requirements], isolating all energy sources [(d)(3)], affixing a lockout device to each energy isolating device [(d)(4)], and verify the equipment energy was isolated and de-energized prior to unjamming the machine [(d)(6)]. b. During die change operations of Switchback machines employees do not isolate all energy sources [per the 1910.147(d)(3) requirements], affix a lockout device to each energy isolation device [(d)(4)], and verify the equipment energy was isolated and de-energized prior to conduction a die change on the machine.