Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1351140.015
Citation: 01001B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $8,000.00
Issuance Date: 01/02/2019
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 02/15/2019
Gravity:
Report ID: 0830500
Contest Date:
Final Order: 01/16/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/16/2019 | $8,000.00 | 02/15/2019 | Other | |
| Penalty | Z: Issued | 01/02/2019 | $0.00 | 01/29/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) MM Packaging Products, Inc, located at 3915 N. Garfield Ave., Loveland, CO 80538: On and preceding 4 October, 2018, the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. Employees perform maintenance, tooling changes and cleaning of Hendrick beam saw. The energy control program provided by the employer showed a procedure for periodic inspection of the Hazardous energy control program, however, no documentation was provided to indicate that inspections have been completed. The following condition exposed employees to caught-in hazards.