Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1350767.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 02/13/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/25/2019
Nr Instances: 3
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 02/12/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2019 | $0.00 | 02/13/2019 | Serious | |
Penalty | Z: Issued | 01/25/2019 | $0.00 | 02/13/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Located at the thread line, the authorized employees were exposed to caught in hazards when performing service and maintenance on the Okuma LU45II lathe (SN: 177784) without training on the purpose and use of energy control procedures. b) Located at the thread line, the authorized employees were exposed to caught in hazards when performing service and maintenance on the Mori Seiki SL-65 (SN: 1212) without training on the purpose and use of energy control procedures. c) Located at the high speed thread line, the authorized employees were exposed to caught in hazards when performing service and maintenance on the Okuma LU35 (SN: 166197) without training on the purpose and use of energy control procedures.