Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1341247.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/21/2018
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 01/23/2019
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 01/10/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/10/2019 | $0.00 | 01/23/2019 | Serious | |
| Penalty | Z: Issued | 12/21/2018 | $0.00 | 01/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. On or about August 22, 2018, employees of Bonduelle working: a. In the Repack Building on the Cob Corn Wrapping Line were exposed to rotating shaft ends which had a protruding Allen Screw. b. In the Cobb Cutting Area were exposed to the rotating shaft and exposed bolts on the lower wheel section of the CCM Cutters.