Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1322299.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,163.00
Current Penalty: $0.00
Issuance Date: 11/20/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 02/19/2019
Gravity: 5
Report ID: 0524530
Contest Date:
Final Order: 12/12/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/12/2018 | $0.00 | 02/19/2019 | Serious | |
Penalty | Z: Issued | 11/20/2018 | $10,163.00 | 12/18/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): The employer did not ensure that the drive gears were completely enclosed, on a full revolution continuous operation power press, identified as priming unit #5, located in the Primer Manufacturing Area. Employees were exposed to machine hazards associated with nip points when accessing the point of operation from the back of the machine.