Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1303753.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/06/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/01/2018
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 07/31/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 07/06/2018 | $0.00 | 08/01/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): The employer is failing to protect employees from struck by and crushing hazards associated with servicing and maintaining equipment with stored energy. The most recent occurrence of this was documented to occur on March 22, 2018 at the facility located at 431 A St. Lincoln, NE 68501when an employee was servicing the bridge tag on a Mack 713 concrete mixer truck without using the a means to secure it and isolate it from the forces of the gravity that caused the bridge tag swing and injure an employee.
Translate