Violation Detail
Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1294192.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/09/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 08/13/2018
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/03/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/03/2018 | $0.00 | 08/13/2018 | Serious | |
| Penalty | Z: Issued | 07/09/2018 | $0.00 | 08/13/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: On or about February 19, 2018, the employer failed to conduct a periodic inspection of their hazardous energy control program at least annually. The last audit of their program was in 2014. The employer failed to identify a pneumatic energy source on the M964, L12 Hydraulic Cutoff Machine as part of their energy control lock out tag out procedures.