Violation Detail
Standard Cited: 19261153 E02
Inspection Nr: 1283871.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/14/2018
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 07/13/2018
Gravity: 10
Report ID: 0213400
Contest Date:
Final Order: 07/05/2018
Related Event Code (REC): R
Emphasis:
Substance: 9000
Substance: 9010
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/05/2018 | $0.00 | 07/13/2018 | Serious | |
Penalty | Z: Issued | 06/14/2018 | $0.00 | 07/13/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.1153(e)(2): Where respirator use is required by this section, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134: a) Power Concrete Co., Inc./Orphan bridge deck on Port Reading Avenue between ProLogis Way and West Avenue in Woodbridge Township, NJ- The employer did not develop and implement a written respiratory protection program with worksite-specific provisions covering respirator selection, care and maintenance, as well as medical clearance and training of users, for those employees who were required to wear Air-purifying respirators. Employee(s) were required to wear tight-fitting air-purifying respirators (APR) with filters for protection from the silica dust when using jackhammers and handheld power saws to cut concrete. Condition observed on or about December 15, 2017.