Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1283514.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/30/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/25/2018
Gravity: 10
Report ID: 0524530
Contest Date:
Final Order: 04/26/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 03/30/2018 | $0.00 | 04/25/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: In the Potting Department of the UNICOR Factory, on the REED Duplimatic, Screw Injection Molding Machine, the space above the mold was not guarded. Employees were exposed to amputation hazards.