Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1280948.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,195.00
Current Penalty: $0.00
Issuance Date: 03/23/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/20/2018
Gravity: 5
Report ID: 0523300
Contest Date: 04/16/2018
Final Order: 08/29/2018
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/29/2018 | $0.00 | 04/20/2018 | Serious | |
| Penalty | C: Contested | 04/18/2018 | $12,195.00 | 04/20/2018 | Serious | |
| Penalty | Z: Issued | 03/23/2018 | $12,195.00 | 04/20/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about December 5, 2017, and on dates prior, employee(s) were not using energy isolating devices to isolate spiral conveyors from energy source(s) prior to performing inspections and cleaning on this equipment. The list of spiral conveyors includes, but is not limited to, the AmbaFlex Spiralveyor SV (Serial No. 60249-05).