Violation Detail
Standard Cited: 19100147 C07 III A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1279360.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/10/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/04/2018
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 05/09/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/09/2018 | $0.00 | 05/04/2018 | Serious | |
| Penalty | Z: Issued | 04/10/2018 | $0.00 | 05/04/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures a) Door Shop: On or about November 28, 2017, employees were exposed to unexpected machine start up after the Norfield Magnum Door Machine router component was replaced with a different model without employee training on effective energy isolation of the new equipment.