Violation Detail
Standard Cited: 19100147 F01 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1265531.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/22/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0317300
Contest Date: 06/13/2018
Final Order: 07/27/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 07/27/2018 | $0.00 | Serious | ||
| Penalty | C: Contested | 06/14/2018 | $0.00 | Serious | ||
| Penalty | Z: Issued | 03/22/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed: a) 1162 Holly Hill Road, Milford, DE: On or about September 22, 2017, the employer failed to ensure that employees were provided with alternative means of protection to prevent unintentional contact with moving parts while troubleshooting and/or inspecting the ZED Thermoformer machine.