Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1263219.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/07/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/27/2017
Gravity: 5
Report ID: 0317700
Contest Date:
Final Order: 11/21/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/21/2017 | $0.00 | 12/27/2017 | Serious | |
| Penalty | Z: Issued | 11/07/2017 | $0.00 | 12/27/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Service Shop: The employer did not conduct a periodic inspection of the energy control procedures including, but not limited to, powered industrial trucks at least annually, on or about September 13, 2017. Abatement Certification Required.
Translate