Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1261043.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/12/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/07/2017
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 11/06/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/06/2017 | $0.00 | 11/07/2017 | Serious | |
| Penalty | Z: Issued | 10/12/2017 | $0.00 | 11/07/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) Planer room: On and before May 10, 2017, employees who perform scheduled and unscheduled maintenance on the Chilco planer, did not recognize and/or acknowledge the hazards of clearing jammed equipment without first positively controlling all energy sources. Note: Abatement certification and documentation is required for this item.