Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1256816.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/26/2018
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 03/05/2018
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 02/07/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/07/2018 | $0.00 | 03/05/2018 | Serious | |
| Penalty | Z: Issued | 01/26/2018 | $0.00 | 02/20/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): Application of control. The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). On or about 28 July 2017, prior to starting work on the machines, to include servicing, maintenance and unjamming of the Vecoplan Retech Grinder RG50 S/N 155801 by manually rotating the belts, employees were not required to apply hazardous energy controls as follows: 1. Prepare for shut down by recognizing energy hazards and its controls, 2. Turn off and shut down the machines, 3. Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, 4. Affix lockout or Tag-out devices to each energy isolating device, 5. Render safe all potentially hazardous stored or residual energy, 6. Verify that isolation and de-energization of the machine or equipment have been accomplished. The employer failed to take the necessary steps to ensure that their employees were properly protected against amputation hazards from unexpected start-up. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Translate