Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1255332.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/04/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 1
Report ID: 0936300
Contest Date:
Final Order: 11/22/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/22/2017 | $0.00 | Serious | ||
| Penalty | Z: Issued | 10/04/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Shipyard and/or m/v Tamaraw: Employee(s) using tight-fitting half-mask elastomeric respirators were not fit tested prior to using them during welding and/or cutting operations. Employees were exposed to respiratory hazards.