Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1253294.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/22/2017
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 09/18/2017
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 09/01/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/01/2017 | $0.00 | 09/18/2017 | Serious | |
| Penalty | Z: Issued | 08/22/2017 | $0.00 | 09/18/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) KITCHEN, AUTOMATIC VOLUME FILLING MACHINE - Employee(s) serviced and maintained the Accutek Automatic Volume Filling machine, which included the clearing of clogs in the lines, and the employer had not provided lockout tag out training to the employee(s) performing the services, which thereby exposed the employee(s) to serious injuries, on or about July 28, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.