Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1250054.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/26/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/06/2017
Gravity: 5
Report ID: 0317900
Contest Date: 10/17/2017
Final Order: 01/22/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/22/2018 | $0.00 | 10/06/2017 | Serious | |
| Penalty | C: Contested | 10/17/2017 | $0.00 | 10/06/2017 | Serious | |
| Penalty | Z: Issued | 09/26/2017 | $0.00 | 10/06/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, an employee performed servicing and maintenance on machinery and equipment to include but not limited to horizontal band saw, press brakes, and cranes where lock out/tagout hardware was used, but the employer had not provided adequate training to ensure that the purpose and function of the energy control program was understood.