Violation Detail
Standard Cited: 19100134 H01 II Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1245161.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/22/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 01/05/2018
Gravity: 5
Report ID: 0524200
Contest Date: 01/18/2018
Final Order: 08/12/2019
Related Event Code (REC):
Emphasis:
Substance: 1591
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/12/2019 | $0.00 | 01/05/2018 | Serious | |
Penalty | C: Contested | 02/06/2018 | $0.00 | 01/05/2018 | Serious | |
Penalty | Z: Issued | 12/22/2017 | $0.00 | 01/05/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
NOTE: Construction Reference: 1926.103. The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(h)(1)(ii): Respirators issued to more than one employee were not cleaned and disinfected before being worn by different individuals: a) On July 6, 2017 the employer did not ensure that employee(s) wearing respiratory protection cleaned and disinfected the respirators as often as necessary to maintain them in a sanitary condition. Two Clemco Apollo 600 Series Supplied Air Respirators (SARs) were stored on top of Axxiom Manufacturing Inc. abrasive blasting pots outside a lead containment located on the 2nd floor. The inside visors of the SARs, issued for common use, were contaminated with up to 23.43 µg lead and 0.637 µg cadmium.