Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1244799.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 01/25/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/20/2017
Nr Instances: 11
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 01/08/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/08/2018 | $0.00 | 01/25/2018 | Serious | |
Penalty | Z: Issued | 12/20/2017 | $0.00 | 01/25/2018 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees, and to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: (a) Perry Tool & Die Co. at 11606 Reed Ct., Broomfield, CO 80020: On and before June 23, 2017 the employer did not provide adequate training to ensure that employees acquired the knowledge and skills necessary for the safe application, usage and removal of energy control devices including, but not limited to the following machines or equipment: (1) Amada press brake models: RG-50, RG-100, RG-35S, and RG3512LD (2) Amada punch press models: 110, Pega-244, VIPROS 255, and VIPROS 357 (3) Amada sheer model: M-3045 (4) Perkins Machine Company punch press model: 300-B (5) Rother Machine Tools press brake, S/N 10VSG/A2066