Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1231790.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/31/2017
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 11/13/2017
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 11/22/2017
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/22/2017 | $0.00 | 11/13/2017 | Serious | |
| Penalty | Z: Issued | 10/31/2017 | $0.00 | 11/13/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Chicago Die Cutting Press 770: On or about May 10, 2017, gravitational energy was not isolated by placing die safety blocks between the upper and lower die when performing die setting and removal. This exposed the press operator to crushing hazard and amputation injury.
Translate