Violation Detail
Standard Cited: 19260416 A03 General requirements.
Inspection Nr: 1224604.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/06/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/30/2017
Gravity: 10
Report ID: 0830300
Contest Date:
Final Order: 07/20/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/20/2017 | $0.00 | 06/30/2017 | Serious | |
| Penalty | Z: Issued | 06/06/2017 | $0.00 | 06/30/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit: (a) On or about March 29, 2017 and at times prior for employees exposed to electrical hazards while performing carpentry work near energized exposed electrical parts where one employee suffered electrocution at or near 1606 Earl Circle in Grand Forks, North Dakota.