Violation Detail
Standard Cited: 19100179 G01 V Overhead and gantry cranes.
Inspection Nr: 1222145.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/21/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 1
Report ID: 0523400
Contest Date:
Final Order: 10/13/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/13/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 09/21/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions. (a) Babbitting Room West Hoist: Columbus McKinnon over head crane hoist number L074J4, pendant control box did not have clear identifying markings for functions of the hoist.