Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1220918.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 06/07/2017 2
Initial Penalty: $12,675.00
Current Penalty: $0.00
Issuance Date: 04/20/2017
Nr Instances: 80
Nr Exposed: 100
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 05/10/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2017 | $0.00 | 06/07/2017 | Serious | |
Penalty | Z: Issued | 04/20/2017 | $12,675.00 | 06/07/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): At 2700 Central Avenue, Poplar Bluff, MO, specifically inside of the Plastic Strip Department, employees were exposed to caught-in hazards on machines such as, but not limited to, an Injection Molded Plastic Collator, m/n PS160, and did not isolate all energy sources prior to clearing jams. This violation was observed on 03/31/17.