Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1220064.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/23/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/10/2017
Gravity: 5
Report ID: 0317900
Contest Date: 07/21/2017
Final Order: 11/03/2017
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/03/2017 | $0.00 | 07/10/2017 | Serious | |
Penalty | C: Contested | 08/17/2017 | $0.00 | 07/10/2017 | Serious | |
Penalty | Z: Issued | 06/23/2017 | $0.00 | 07/10/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Niagara Bottling, LLC. - On or about March 23, 2017, the employer did not provide adequate training of employees in that written training material, specific lockout procedures, Lock Out Tag Out Program, and Preventative Maintenance Script Checklists, were all in English and not in the primary language of all authorized employees.