Violation Detail
Standard Cited: 19100119 K01 Process safety management of highly hazardous chemicals.
Inspection Nr: 1217588.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 05/30/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/23/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 06/05/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/05/2017 | $0.00 | 05/30/2017 | Serious | |
Penalty | Z: Issued | 05/23/2017 | $0.00 | 05/30/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.119(k)(1): The employer did not issue a hot work permit for hot work operations conducted on or near a covered process: (a) A hot work permit was not requested or provided by Millercoors LLC for a truck driver permitted to use a torch, in the ammonia equipment room, building 1A, at 4001 State Street Milwaukee, Wisconsin 53208 when delivering caustic on March 16, 2017.