Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1215670.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/20/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 05/10/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/20/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Warehouse, Machine Area - on or about March 3, 2017, employees performed servicing on a Travelling Head Hydraulic Cutting Machine, THNC-2570, adjusting the travelling head by reaching above the plate and engaging a switch to adjust the height of the head from the work table; the employer failed to ensure the control of energy by use of unplugging the cord and plug.