Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1207476.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/19/2017
Nr Instances: 2
Nr Exposed: 7
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 05/08/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/08/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/19/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 2/1/2017 in the Baldwin Press Plant area at 1700 Old Covington Highway, Conyers, GA: The employer did not perform annual periodic inspection on the Baldwin Press equipment in the P2 North and South areas, exposing the employees to amputation hazard. The employers last periodic inspection of their written energy control procedures for the Baldwin Defiance Model 20 Press were performed 11/30/2015.