Violation Detail
Standard Cited: 19101000 E Air contaminants.
Inspection Nr: 1204566.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/22/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/07/2017
Gravity: 10
Report ID: 0830300
Contest Date:
Final Order: 07/13/2017
Related Event Code (REC): R
Emphasis:
Substance: 0560
Substance: C730
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/13/2017 | $0.00 | 07/07/2017 | Serious | |
| Penalty | Z: Issued | 06/22/2017 | $0.00 | 07/07/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000 (a) through (d): (a) On or about January 12, 2017, for an employee exposed to carbon monoxide levels at mean calculated 682.8 ppm for approximately 240 minutes., 8-hour Time-Weighted Average of 341.4 ppm in excess of the OSHA's Permissible Exposure Limit of 50 ppm while repairing slide the use of an approximately 260.6 lb. Honda EU6500is generator inside of an enclosed equipment trailer on the Continental Holstein 5 Well Pad approximately 5 miles north of Highway 23 near New Town, North Dakota.