Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1192537.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 06/04/2018 3
Initial Penalty: $0.00
Current Penalty: $12,500.00
Issuance Date: 04/28/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 5
Report ID: 0521400
Contest Date: 05/17/2017
Final Order: 05/03/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/03/2018 | $12,500.00 | 06/04/2018 | Serious | |
Penalty | C: Contested | 05/18/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/28/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about November 5, 2016, employees on the Comfort Bath Cleansing System Line 1 were exposed to amputations when performing setup activities, such as hand threading rolled sheet foam into the in-feed rollers of the slitter. The employer did not conduct a periodic inspection of the energy control procedures, at least annually, to ensure that the procedures and the requirements of the standard were being followed. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).