Violation Detail
Standard Cited: 19260757 A06 Open web steel joists.
Inspection Nr: 1183716.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 02/13/2017 2
Initial Penalty: $8,873.00
Current Penalty: $0.00
Issuance Date: 02/07/2017
Nr Instances: 4
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/24/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/24/2017 | $0.00 | 02/13/2017 | Serious | |
Penalty | Z: Issued | 02/07/2017 | $8,873.00 | 02/13/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.757(a)(6): When steel joist(s) are landed on a structure, they shall be secured to prevent unintentional displacement prior to installation. Located within Sequence 17 Music Wing on October 10 and/or 11, 2016 prior to installation at final erection connection points Table A type short span open web steel bar joist series 22K7-J240 and 22K9-J237 both exceeding 40 foot 7 inches span were landed on the joist pocket structure with crane supported load lines releasing joist load prior to being welded on both sides of the seat of one end of each steel joist exposing employees to the hazard of being struck by unintentional joist displacement from the joist pocket bearing points.