Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1172160.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,126.00
Current Penalty: $0.00
Issuance Date: 12/29/2016
Nr Instances: 1
Nr Exposed: 250
Abatement Date: 02/06/2017
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 01/24/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/24/2017 | $0.00 | 02/06/2017 | Serious | |
Penalty | Z: Issued | 12/29/2016 | $7,126.00 | 02/06/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about 24 August 2016, the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed for the following types of machines: shears, brake presses, laser cutting machines and lathes. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).