Violation Detail
Standard Cited: 19100333 C03 III A Selection and use of work practices
Inspection Nr: 1170083.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/14/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 03/02/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/02/2017 | $0.00 | Serious | ||
| Penalty | Z: Issued | 02/14/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.333(c)(3)(iii)(A): Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. (a) 775 Highway 16 W. Newnan, GA. The employer did not ensure the Comet Series 75 truck crane maintained a 10 foot clearance from the boom load line to energized high voltage overhead power lines. Employees were exposed to electrical shock.