Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1111049.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/08/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/14/2016
Gravity: 5
Report ID: 0213900
Contest Date: 06/29/2016
Final Order: 12/14/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/14/2016 | $0.00 | 06/14/2016 | Serious | |
Penalty | C: Contested | 06/29/2016 | $0.00 | 06/14/2016 | Serious | |
Penalty | Z: Issued | 06/08/2016 | $0.00 | 06/14/2016 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Boccella Precast LLC. - Storage area: Acetylene and oxygen compressed gas cylinders were not secured from being knocked over, on or about 12/15/2015