Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1098774.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/31/2016
Nr Instances: 1
Nr Exposed: 89
Abatement Date: 05/17/2016
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 05/04/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2016 | $0.00 | 05/17/2016 | Serious | |
Penalty | Z: Issued | 03/31/2016 | $0.00 | 05/17/2016 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) The energy control procedure for the MKE1 KSAW Tracker robot, station - 3308 did not account for the gravitational energy presented by the tote/bin elevator.