Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1092367.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 11/16/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/21/2015
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 12/10/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/10/2015 | $0.00 | 11/16/2015 | Serious | |
Penalty | Z: Issued | 10/21/2015 | $0.00 | 11/16/2015 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Cardington Yutaka Technologies, Inc. on or about September 09, 2015, at the address of 575 West Main St. Cardington, OH: The employer failed to ensure that energy isolating procedures for shutdown were performed prior to conducting tool adjustments on the Double End Forming Machine (#320052) on line #6. Employees performing these task in energized condition were exposed to amputation hazards at or near the machines point of operation, in that energy control shutdown procedures required under 29 CRF 1910.147(d)(2) were not utilized before the employee began the aforementioned work task on the machine.