Violation Detail
Standard Cited: 19260062 C01 Lead
Inspection Nr: 907402.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 11/11/2013 5
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 11/01/2013
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 12/30/2013
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/01/2013 | $2,800.00 | 11/11/2013 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.62(c)(1): Employee(s) were exposed to lead at concentrations greater than fifty micrograms per cubic meter of air averaged over an eight-hour period: On or about May 14, 2013, at the residential home remodeling project located at 2621 Prytania St., New Orleans, LA, the employer did not protect at least two employees from exposure to lead in excess of 0.050 milligrams per cubic meter (Permissible Exposure Limit) as an 8-hour Time Weighted Average while removing paint from the exterior siding using a power sander. The work was performed in an unsealed containment on the east side of the house. The employees were documented to be exposed to airborne lead levels that ranged from 2.19 mg/m(3) to 14.74 mg/m(3), which is equivalent to 43.8 and 294.79 times the PEL. These exposures were determined from two 309 minute samples. Zero exposure was assumed for the un-sampled 171 minute period per sample. Employees were exposed to the hazards of systemic poisoning from airborne lead.