Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 897452.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 05/24/2013 2
Initial Penalty: $4,000.00
Current Penalty: $3,000.00
Issuance Date: 04/30/2013
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0728900
Contest Date:
Final Order: 05/17/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/17/2013 | $3,000.00 | 05/24/2013 | Serious | |
Penalty | Z: Issued | 04/30/2013 | $4,000.00 | 05/24/2013 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): At the facility in the mechanical room the employer is failing to ensure that the pulley used to transmit power to on the CP4 Ammonia refrigeration pump was not guarded in accordance with this subpart.