Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 897383.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 05/20/2013 2
Initial Penalty: $3,500.00
Current Penalty: $1,750.00
Issuance Date: 05/01/2013
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 05/23/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/23/2013 | $1,750.00 | 05/20/2013 | Serious | |
Penalty | Z: Issued | 05/01/2013 | $3,500.00 | 05/20/2013 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: Machine Area - The energy control procedures for the Juki KE-760L and the Juki 2050 provided generic procedures, rather than specific procedures, for verifying the effectiveness of lockout devices, tagout devices, and dissipating pneumatic energy.