Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 329079.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,500.00
Issuance Date: 07/13/2012
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 08/12/2013
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 08/03/2012
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/03/2012 | $3,500.00 | 08/12/2013 | Serious | |
Penalty | Z: Issued | 07/13/2012 | $5,000.00 | 08/12/2012 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) TRW Automotive, U.S. LLC, on or about 6/21/12: The employer has not conducted a periodic or more frequent inspection of their energy control procedures to ensure that the requirements of the standard were being followed. Employees perform servicing and maintenance on machines and equipment such as but not limited to: Calvary Pre-Heat & Selective Solder System, Automated Robot and Gasket/PCBA/Battery Assembly to Housing machine.